Drylining Knowledge Centre

Drylining Knowledge Centre

The National Drylining Knowledge Centre has been created to help contractors, architects, estimators, developers and procurement teams better understand modern drylining systems, fire rated partitions, acoustic wall systems, metal framing and technical design considerations.

C Stud Systems
I Stud Systems
Fire Rated Systems
Acoustic Systems
Deflection Heads
Shaftwall Systems

What Is Drylining?

Drylining is a modern construction method used to create internal walls, ceilings and linings using lightweight steel framing, insulation and plasterboard systems.

Compared with traditional masonry construction, drylining systems provide improved flexibility, faster installation, reduced structural loading and enhanced fire and acoustic performance.

C Stud vs I Stud

Feature C Stud I Stud
Typical Use General Partitioning High Performance Partitions
Wall Heights Standard Heights Higher Partitions
Acoustic Performance Good Enhanced
Rigidity Standard Increased
Common Applications Commercial & Residential Healthcare, Education, Hotels

Common Stud Sizes

Stud Size Typical Applications
50mm Internal partitions, wall linings and smaller commercial spaces.
70mm Commercial partitions and office fit outs.
92mm Acoustic walls and increased partition heights.
146mm High performance fire and acoustic wall systems.

Typical Drylining Partition Build-Up

Board Stud Insulation Stud Board

The final fire and acoustic performance depends upon the complete tested system including framing, board configuration, insulation and installation method.

Fire Rated Systems

Fire Rating Typical Application
30 Minutes Basic compartmentation requirements.
60 Minutes General commercial and residential projects.
90 Minutes Enhanced fire protection requirements.
120 Minutes Healthcare, education and specialist environments.

Fire performance is achieved through tested system build-ups and should not be considered as a property of individual components in isolation.

Acoustic Performance Guide

Performance Typical Use
40dB Standard office and internal walls.
45dB Residential internal walls.
50dB Improved residential performance.
55dB Hotels and educational facilities.
60dB+ Healthcare, studios and specialist environments.

Deflection Heads & Structural Movement

Deflection heads are designed to accommodate movement in the supporting structure without transferring loads into the partition system.

Typical Deep Leg Track Deflection Head Stud Deep Leg Track Soffit

Movement allowances should always be coordinated with structural design requirements and project-specific details.

System Design Considerations

  • Fire resistance requirements
  • Acoustic performance targets
  • Structural movement allowances
  • Partition heights
  • Door and service openings
  • Mechanical and electrical services
  • Impact requirements
  • Moisture and environmental conditions

Frequently Asked Questions

What is the difference between a C Stud and an I Stud?

I Studs are typically used where greater rigidity, increased partition height and enhanced acoustic performance are required.

Can a drylining wall provide both fire and acoustic performance?

Yes. Many partition systems are designed to achieve both fire resistance and acoustic performance when constructed in accordance with tested system requirements.

When should a deflection head be used?

Deflection heads are generally required where movement in the supporting structure could affect the partition wall.

How do I choose the correct stud size?

Stud selection depends on wall height, fire performance, acoustic targets, opening sizes and project-specific requirements.

Need Technical Support?

Our team can assist with wall build-ups, fire rated systems, acoustic systems, material take-offs, stud selection and project-specific quotations.